Setup
Power Blazer 359
Path OAM
Path OAM
From the test menu, tap Setup, Test Configurator and tap on the Clients
block and on the Path OAM tab.
Path OAM check box when selected (cleared by default) enables the
use of Path OAM configuration and monitoring including APS function.
OAM Responder check box when selected (default) enables the path
OAM responder to respond to the 2DMM messages.
Global Pass/Fail Verdict check box when selected (default) enables
the global Path OAM pass/fail verdict.
Path OAM on Client ID allows selecting on which client ID the path
OAM applies.
Basic OAM
CC Function check box when selected (default) allows generating and
monitoring Basic OAM messages.
Period allows selecting the transmission period of the Basic OAM
Message: 16K, 32K, 64K (default), 512K.
Bidirectional Delay Measurement
2DM Function check box when selected (cleared by default) enables
the bidirectional delay measurement function.
TX Enable check box when selected (cleared by default) allows
transmitting 2DMM messages once the test is started. When the delay
measurement generation is not continuous, the TX Enable check box
is automatically cleared once all messages have been transmitted.
Period allows entering the transmission period of the 2DMM
multi-block messages: 1 s, 10 s (default), or 1 min.