EasyManua.ls Logo

EXFO FTBx-88260 - Traces - SONET;SDH

EXFO FTBx-88260
1071 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Results
634 FTBx-88000 Series
Traces - SONET/SDH
Traces - SONET/SDH
From the test menu, tap Results, Traces, and if available the SONET/SDH
sub-tab.
Note: Selecting a Trace byte to be generated will automatically update the
corresponding OH byte. Refer to OH - SONET/SDH on page 710 for more
information. Configuration is coupled with settings from Traces -
SONET/SDH on page 456.
Traces
Section (J0) / RS (J0), STS Path (J1) / AU Path (J1) / TU-3 Path (J1),
VT Path (J2) / TU Path (J2) displays the received J0/J1/J2 value in 16 or
64-bytes format. The <crc7> represents the CRC-7 for a 16-bytes
format. The last two bytes of a 64-bytes format, <C
R
> and <L
F
>,
represent respectively a carriage return and a line feed.
TIM-S / RS-TIM, TIM-P / HP-TIM, TIM-V / LP-TIM check box when
selected (cleared by default) enables the corresponding Trace
Identifier Mismatch for the expected message defined.
Format allows the selection of the expected format:
16 Bytes (default), or 64 Bytes.
Expected allows entering the expected J0 trace message.
Copy RX allows using the received SAPI/DAPI message as the
expected one.