Test Results
Power Blazer 561
Summary - eCPRI BERT
Summary - eCPRI BERT
From the test menu, tap Results, and the Summary tab.
Global/<Port #>, available with Dual Port topology, allows selecting to
display a brief summary for both ports (Global) or for a specific port.
Test Status displays the current status of the test. The global test pass/fail
verdict is displayed next to the Test Status field when enabled.
--: Idle state, the test is not running or results are not available.
In Progress: The test is running.
Completed: The test is completed, stopped at the planned time, or
manually stopped when there is no set timer.
Aborted: The test is interrupted; stopped before the set timer.
LOPPS-L: For One-Way Latency mode, the test is interrupted due to a
failure of synchronization with the 1PPS clock (LOPPS-L).
Not Ready-R: The test is interrupted because the Measurement Role of the
peer is either Mismatch-R or Inactive-R. Check the eCPRI Flow at each end
of the eCPRI circuit to determine the fault.
Start Time indicates the date and time the test was started. The date and
time reset every time the test is restarted or reset.
Test Recovery, when displayed, indicates that the test has automatically
recovered from a power failure. The number of occurrences is also
displayed next to the Test Recovery field. Refer to Power Failure Recovery
on page 789.
Logger Full, when displayed, indicates that the logger is full. Refer to
Logger on page 496.