Setup
Power Blazer 369
RFC 2544 - Global
RFC 2544 - Global
From the test menu, tap Setup, Test Configurator, tap on the RFC 2544
block, and on the Global tab.
Dual Test Set
Dual Test Set (DTS) check box when selected (cleared by default)
enables the Dual Test Set testing mode. Once Dual Test Set is
enabled, use the Discover Remote button to select a remote unit. Not
available in Dual Port topology.
Note: It is also possible using the Discover Remote button to connect to a remote
unit and automatically enable Dual Test Set. For more details, refer to
Discover Remote on page 764.
Disconnected indicates that there is no connection established with a
remote unit.
Connected indicates that the connection is established with a remote
unit.
Discover Remote allows discovering remote unit supporting Remote
Loopback and/or Dual Test Set. For more details, refer to Discover
Remote on page 764.
Global Options
Flow Direction allows the selection of the traffic direction as follows:
TX to RX for Single Port topology.
Port <m> to Port <n>, Port <n> to Port <m>, and
Bidirectional for Dual Port topology.
Local to Remote, Remote to Local, or Bidirectional for Dual Test
Set.