Setup
448 FTBx-88000 Series
Time Error / Wander
Duration check box when selected (cleared by default) allows
selecting/entering the test duration: 15 minutes, 1/2/4/6/12/24/72
hours, or User Defined (1 second up to 30 days depending on the
selected Sampling Rate); with the G.8275.2 profile, the duration
should be more than 200 seconds in order to obtain TE values.
Note: Once the test completes (after the duration is reached or when manually
stopped), MTIE calculation may take some time depending on the test
duration and sampling rate used.
For Time Error measurements:
cTE Averaging Period (s), available with either G.8275.1 profile or
1PPS interface, defines the averaging period used to calculate the
constant Time Error (cTE) value over a specific period of time: Elapsed
time (default), 100 s, 500 s, 1000 s, 10000 s.
dTE
H
Observation Period (s), available with either G.8275.1 profile or
1PPS interface, defines the observation period used for qualifying the
Time Error after High-Pass filtering 0.1 Hz: 100 s, 500 s, 1000 s, 10000 s
(default).
G.8261- CES Case 1 - 2048 kbit/s (MRTIE) X -
G.8261- CES Case 1 - 1544 kbit/s X -
G.8261- CES Case 2A - 2048 kbit/s (MRTIE) X -
G.8261- EEC Option 1 - SyncE Interface X X
G.8261- EEC Option 2 - SyncE Interface - X
G.8261.1- PEC-Slave Frequency Case 3 X -
G.8262- EEC Option 1- SyncE - Constant Temperature X X
G.8262- EEC Option 1- SyncE - Variable Temperature X -
G.8262- EEC Option 2- SyncE - Constant Temperature X X
G.8263- PEC-Slave Frequency - Constant Temperature X -
G.8263- PEC-Slave Frequency - Variable Temperature X -
G.8271.1- Dynamic Time Error X -
Mask MTIE TDEV