Test Results
Power Blazer 575
Summary - FC BERT
Service Disruption
Note: Only available on the FTBx-88260 module. Service disruption results are
only available when Disruption Monitoring is enabled; when disabled the
message Service disruption monitoring disabled is displayed. Refer to
Service Disruption on page 286).
Disruption Time is the time during which there is a disruption of
service due to the absence of traffic. The service disruption event lasts
until valid FC frames are received for at least the Debounce Time
without any service disruption event. The following measured
disruption time values are reported: Longest Shortest, Last, Average,
and Total. Total indicates the total duration of all measured disruption
times.
Disruption Count indicates the number of disruption events detected
since the beginning of the SDT test.
Note: When a disruption event is equal to or longer than the test period which is
fixed to 5 minutes, then the measured disruption time is equal to the test
period.
SDT Threshold allows configuring the acceptable maximum service
disruption time before failing the test: 0.005 to 299999.999 ms (default
is 50 ms). The threshold value cannot be less than the No Traffic Time
value.