Test Results
Power Blazer 579
Summary - FlexE BERT
Path OAM Client
The Pass/Fail verdict is displayed when enabled. A fail verdict is
declared when any of the following alarms/errors occurs excluding
CRC4: FlexE Client Link Down error, Basic OAM alarms/errors, CV
alarms, or CS Type alarms.
Client ID indicates the client identification number and allows
displaying the Path OAM for the client (see Summary - Path OAM -
FlexE BERT on page 581).
CC Status indicates the Basic OAM CC Status: Green - no alarm; Red -
alarm active; Gray - pending state.
CV Status indicates the Connectivity Verification Status: Green - no
alarm; Red - alarm active; Gray - pending state.
CS Type Status indicates the CS Type Status: Green - no alarm; Red -
alarm active; Gray - pending state.
Max Delay indicates the Delay Measurement maximum value.