Alarms/Errors
Power Blazer 917
Alarms
Domain Mismatch for 1588 PTP with G.8275.1 profile, indicates that
none of the received Domain values match the configured value (refer
to page 211).
ERDI-PCD / ERDI-CD (ERDI - Connectivity Defect) for SONET/SDH,
indicates that bits 5, 6, and 7 of the G1 byte contain the “110” pattern in
five consecutive frames. In TX, generates a “110” pattern for bits 5, 6,
and 7 of the G1 byte.
ERDI-PCD (Enhanced RDI - Path Connectivity Defect) for WIS,
indicates that bits 5, 6 and 7 of the G1 byte contain the “110” pattern in
five to ten consecutive frames.
ERDI-PPD / ERDI-PD (ERDI - Payload Defect) for SONET/SDH, indicates
that bits 5, 6, and 7 of the G1 byte contain the “010” pattern in five
consecutive frames. In TX, generates a “010” pattern for bits 5, 6, and 7
of the G1 byte.
ERDI-PPD (Enhanced RDI - Path Payload Defect) for WIS, indicates that
bits 5, 6 and 7 of the G1 byte contain the “010” pattern in five to ten
consecutive frames.
ERDI-PSD / ERDI-SD (ERDI - Server Defect) for SONET/SDH, indicates
that bits 5, 6, and 7 of the G1 byte contain the “101” pattern in five
consecutive frames. In TX, generates a “101” pattern for bits 5, 6, and 7
of the G1 byte.
ERDI-PSD (Enhanced RDI - Path Server Defect) for WIS, indicates that
bits 5, 6 and 7 of the G1 byte contain the “101” pattern in five to ten
consecutive frames.
ERDI-VCD (Enhanced Remote Defect Indication - Connectivity Defect)
for SONET/SDH, indicates that bits 5, 6, and 7 of the Z7 (SONET) / K4
(SDH) byte contain the “110” pattern, and bit 8 of the V5 byte contain
“1”, in five consecutive VT/LP superframes. In TX, generates a “110”
pattern for bits 5, 6, and 7 of the Z7 (SONET) / K4 (SDH) byte, and “1”
for bit 8 of the V5 byte.