CHAPTER 21
PAGE 7
PAGE DATE: 7. July 2010
MAINTENANCE MANUAL EXTRA 300LT
2 Remove main and bottom fuselage cover as per chapter 53.
3 Disconnect Bowden cable from the inlet box actuator arm
(14).
4 Remove clamp sheet (12, 15) attachment bolts on the
firewall.
5 Loosen hose clamp (11).
6 Mark main Bowden cable (4) routing and remove the
attachment self-clinching plastic straps (5).
7 Remove attachment nut and washer (7) of the main control
unit (1).
8 Pull the main control unit (1) with the complete Bowden
cable (4) aft to remove from aircraft. Secure label plate (8),
clamp sheets (12, 15) and attachment nut and washer (7).
Installation
Refer to figure 3.
1 Thread the Bowden cable (4) end through the respective
attachment tube (6).
2 Thread the attachment nut and washer (7) on the Bowden
cable
3 Ensure nut (9) is fastened.
4 Place label plate (8) and align.
5 Attach the main control unit (1) and the label plate (8) by
means of its attachment nut and washer (7).
6 Position the Bowden cable (4) along the prior marked
routing.
7 Fasten the Bowden cable (4) with self-clinching plastic
straps (5) in place.
8 Thread the Bowden cable end through the hoseclamp (11).
9 Thread the Bowden cable through the firewall.
10 Renew the sealing of the clamp sheets (12, 15). Use PRC
812 sealant.