EasyManua.ls Logo

Extra 300LT - General; Operating Time; Temperature Limit

Extra 300LT
551 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4
PAGE 4
PAGE DATE: 30. April 2010
MAINTENANCE MANUAL EXTRA 300LT
04-00-00 GENERAL
For each inspection listed here, refer to the applicable
chapter in this manual.
I M P O R T A N T It is the operator's responsibility to make sure that time
limits or life limits for items in this chapter are not
exceeded.
The airworthiness limitations items include mandatory
replacement times and structural inspection intervals which
may only be changed with permission of the applicable
airworthiness authority.
This airworthiness limitation section is approved by the
regulatory authority and specifies maintenance required
under paragraphs 43.16 and 91.403 of the Federal Aviation
Regulations, unless an alternative program has been ap-
proved by the regulatory authority.
04-00-01 Temperature Limit
Composite structure is qualified up to 72°C (162°F). Struc-
ture temperatures above this limit are not approved. Not to
exceed this temperature limit, only appropriate colour speci-
fication for composite structure as given by the manufac-
turer document EA-03205.19 must be used when finish
restoration is required.
In case of doubt regarding to the classification of colour,
contact EXTRA-Flugzeugproduktions- und Vertriebs-GmbH.
04-00-02 Operating Time
Only the airframe and components as listed in Chapter 04-
10-00 are subject to a permissible operating time; concern-
ing all other components recommended replacement times
are given in Chapter 05-10-03.

Table of Contents

Other manuals for Extra 300LT

Related product manuals