96-8100 1-15-96
184
PARAMETERS
SERVICE
MANUAL
VF-SERIES
Parameter 62 SHUTTLE START DELAY
Maximum delay allowed in start of tool shuttle. Units are milliseconds. After
this time, an alarm is generated.
Parameter 63 SHUTTLE STOP DELAY
Maximum delay allowed in motion of tool shuttle. Units are milliseconds.
After this time, an alarm is generated.
Parameter 64 Z TOOL CHANGE OFFSET
For Z-axis; displacement from home switch down to tool change position and
machine zero. About 4.6 inches so for a 2000 line encoder this gives:
4.6 x 33867 = 155788
Parameter 65 NUMBER OF TOOLS
Number of tool positions in tool changer. This number must be 20 for the
present VMC configuration.
Parameter 66 SPINDLE ORI DELAY
Maximum delay allowed when orienting spindle. Units are milliseconds. After
this time, an alarm is generated.
Parameter 67 GEAR CHANGE DELAY
Maximum delay allowed when changing gears. Units are milliseconds. After
this time, an alarm is generated.
Parameter 68 DRAW BAR MAX DELAY
Maximum delay allowed when clamping and unclamping tool. Units are
milliseconds. After this, time an alarm is generated.
Parameter 69 A AIR BRAKE DELAY
Delay provided for air to release from brake on A-axis prior to moving. Units
are milliseconds.
Parameter 70 MIN SPIN DELAY TIME
Minimum delay time in program after commanding new spindle speed and
before proceeding. Units are milliseconds.
Parameter 71 DRAW BAR OFFSET
Offset provided in motion of Z-axis to accommodate the tool pushing out of
the spindle when unclamping tool. Units are encoder steps.
Parameter 72 DRAW BAR Z VEL UNCL
Speed of motion in Z-axis to accommodate tool pushing out of the spindle
when unclamping tool. Units are encoder steps per second.
Parameter 73 SP HIGH G/MIN SPEED
Command speed used to rotate spindle motor when orienting spindle in high
gear. Units are 5000/256 RPM.