Parameter 74 SP LOW G/MIN SPEED
Command speed used to rotate spindle motor when orienting spindle in low
gear. Units are 5000/256 RPM.
Parameter 75 GEAR CHANGE SPEED
Command speed used to rotate spindle motor when changing gears. Units are
5000/256RPM.
Parameter 76 LOW AIR DELAY
Delay allowed after sensing low air pressure before alarm is generated. Alarm
skipped if air pressure returns before delay. Units are 1/50 seconds.
Parameter 77 SP LOCK SETTLE TIME
Required time in milliseconds that the spindle lock must be in place and stable
before spindle orientation is considered complete.
Parameter 78 GEAR CH REV TIME
Time in milliseconds before motor direction is reversed while in a gear change.
Parameter 79 SPINDLE STEPS/REV
Sets the number of encoder steps per revolution of the spindle. Applies only
to rigid tapping option.
Parameter 80 MAX SPIN DELAY TIME
The maximum delay time control will wait for spindle to get to commanded
speed or to get to zero speed. Units are milliseconds.
Parameter 81 M MACRO CALL O9000
M code that will call O9000. Zero causes no call.
Parameter 82 M MACRO CALL O9001 same as 81
Parameter 83 M MACRO CALL O9002 same as 81
Parameter 84 M MACRO CALL O9003 same as 81
Parameter 85 M MACRO CALL O9004 same as 81
Parameter 86 M MACRO CALL O9005 same as 81
Parameter 87 M MACRO CALL O9006 same as 81
Parameter 88 M MACRO CALL O9007 same as 81
Parameter 89 M MACRO CALL O9008 same as 81
Parameter 90 M MACRO CALL O9009 same as 81
Parameter 91 G MACRO CALL O9010
G code that will call O9010. Zero causes no call.
Parameter 92 G MACRO CALL O9011 same as 91
Parameter 93 G MACRO CALL O9012 same as 91
Parameter 94 G MACRO CALL O9013 same as 91
Parameter 95 G MACRO CALL O9014 same as 91
Parameter 96 G MACRO CALL O9015 same as 91
Parameter 97 G MACRO CALL O9016 same as 91
Parameter 98 G MACRO CALL O9017 same as 91
Parameter 99 G MACRO CALL O9018 same as 91