1-15-96 96-8100
187
TABLE OF CONTENTS
PARAMETERS
SERVICE
MANUAL
VF-SERIES
Parameter 114 Y ACC/DEC T CONST
Same definition as Parameter 113
Parameter 115 Z ACC/DEC T CONST
Same definition as Parameter 113
Parameter 116 A ACC/DEC T CONST
Same definition as Parameter 113
Parameter 117 LUB CYCLE TIME
If this is set nonzero, it is the cycle time for the lube pump and the Lube
pressure switch option is checked for cycling in this time. It is in units of 1/50
seconds.
Parameter 118 SPINDLE REV TIME
Time in milliseconds to reverse spindle motor.
Parameter 119 SPINDLE DECEL DELAY
Time in milliseconds to decelerate spindle motor.
Parameter 120 SPINDLE ACC/DECEL
Accel/decel time constant in steps/ms/ms for spindle motor.
Parameter 121 X PHASE OFFSET
The motor phase offset for X motor. This is arbitrary units.
Parameter 122 Y PHASE OFFSET
See Parameter 121 for description.
Parameter 123 Z PHASE OFFSET
See Parameter 121 for description.
Parameter 124 A PHASE OFFSET
See Parameter 121 for description.
Parameter 125 X GRID OFFSET
This parameter shifts the effective position of the encoder Z pulse. It can
correct for a positioning error of the motor or home switch.
Parameter 126 Y GRID OFFSET
See Parameter 125 for description.
Parameter 127 Z GRID OFFSET
See Parameter 125 for description.
Parameter 128 A GRID OFFSET
See Parameter 125 for description.
Parameter 129 GEAR CH SETTLE TIME
Gear change settle time. This is the number of one millisecond samples that
the gear status must be stable before considered in gear.