96-8100 1-15-96
190
PARAMETERS
SERVICE
MANUAL
VF-SERIES
Parameter 162 B STEPS/REVOLUTION
See Parameter 12 for description.
Parameter 163 B BACKLASH
See Parameter 13 for description.
Parameter 164 B DEAD ZONE
See Parameter 14 for description.
Parameter 165 IN POSITION LIMIT B
Same definition as Parameter 101.
Parameter 166 B MAX CURRENT
Same definition as Parameter 105.
Parameter 167 D*D GAIN FOR B
Second derivative gain in servo loop.
Parameter 168 B ACC/DEC T CONST
Same definition as Parameter 113.
Parameter 169 B PHASE OFFSET
See Parameter 121 for description.
Parameter 170 B GRID OFFSET
See Parameter 125 for description.
Parameter 171 B EXACT STOP DIST.
See Parameters 134 for description.
Parameter 172 B FRICTION FACTOR
See Parameter 138 for description.
Parameter 173 B ACCEL FEED FORWARD
Same description as Parameter 145.
Parameter 174 SPINDLE B TEMP. COEF.
This parameter controls the amount of correction to the B-axis in response to
heating of the spindle head. It is 10 times the number of encoder steps per
degree F.
Parameter 175 B AIR BRAKE DELAY
Delay provided for air to release from brake on B-axis prior to moving. Units are
milliseconds.
Parameter 201 X SPINDLE TEMP. COEF.
This parameter controls the amount of correction to the X-axis in response to
heating of the spindle head. It is 10 times the number of encoder steps per
degree F.