Parameter 202 X AIR BRAKE DELAY
This parameter is not used.
Parameter 203 Y AIR BRAKE DELAY
This parameter is not used.
Parameter 204 Z AIR BRAKE DELAY
This parameter is not used.
Parameter 205 A SPINDLE TEMP. COEF.
This parameter controls the amount of correction to the A-axis in response to
heating of the spindle head. It is 10 times the number of encoder steps per
degree F.
Parameter 206 SPIGOT POSITIONS
Maximum number of spigot positions.
Parameter 207 SPIGOT TIMEOUT (MS)
Maximum timeout allowed for spigot to traverse one spigot location.
Parameter 208 SPIN. FAN OFF DELAY
Delay for turning the spindle fan off after the spindle has been turned off.
Parameter 209 COMMON SWITCH 2
Parameter 209 is a collection of general purpose single bit flags used to turn
some functions on and off. The left and right cursor arrows are used to select
the function being changed. All values are 0 or 1 only. The function names are:
HORZ T.C. Enables tool changer for horizontal machining centers (HS models only).
RST STOPS T.C. Tool changer can be stopped with RESET button.
M21-28 @ 540 When enabled (1), M21-M28 is installed at cable 540.
ENA CONVEYOR Enables chip conveyor, if machine is so equipped.
50% RPD KBD When (1) the control will support the new style keyboards with the 50% rapid
traverse key. For controls without a 50% rapid keypad set this bit to (0).
FRONT DOOR When enabled the control will look for an additional door switch and will
generate an operator message.
TC Z NO HOME In Horizontal mills only. This bit prevents Z-axis motion to machine zero prior to
a tool change.
M36 AUTO MOT In Horizontal only. When set to (1), an M36 rotates the A-axis after the PART
READY button is pressed.
AUX AXIS TC In Horizontal mills only. When enabled, means the tool changer carousel is
driven by an aux. axis.
SPIGOT KEY INV When (1) the commands to the conveyor motor are reversed so that forward
becomes reverse. If the conveyor is wired incorrectly, this bit can be set so
that the conveyor runs in the proper direction.