9.7 Network Parameters Sengs
Set device network parameters, including the NIC type, DHCP, and
HTTP.
On the Device for Management page, click → Network →
Network Parameters to enter the Network Parameters
Sengs
tab.
NIC Type
Select a NIC type from the drop-down list. You can select either
Self-adapve, 10M, or 100M.
DHCP
If you disable the funcon, you should manually set the
device's IPv4 address, IPv4 subnet mask, IPv4 default gateway,
MTU, and port.
If you enable the
funcon, the system will automacally assign
IPv4 address, IPv4 subnet mask, IPv4 default gateway for the
device.
HTTP
Set the HTTP port, DNS1 server address, and DNS2 server
address.
9.8 Report Strategy Sengs
You can set the center group for uploading the log via the EHome
protocol.
On the Device for Management page, click
→ Network →
Report Strategy to enter the Report Strategy
Sengs tab.
You can set the center group and the system will transfer logs via
EHome protocol. Click Save to save the sengs.
Center Group
Select a center group from the drop-down list.
Main Channel
The device will communicate with the center via the main
channel.
Note
N1 refers to wired network.
9.9 Network Center Parameters Sengs
You can set the nofy surveillance center, center's IP address, the
port No., the protocol (EHome), the EHome account user
name,etc. to transmit data via EHome protocol.
On the Device for Management page, click Remote
Conguraon
→ Network → Network Center Parameters to enter the Network
Center Parameters
Sengs tab.
Select a center from the drop-down list.
Aer enabling the funcon, you can set the center's address type,
IP address/domain name, and port No., create EHome user name,
etc.
Note
If set the EHome type as EHome5.0, you should create an EHome
key as well.
Click Save.