Note
•
Remember the EHome account and EHome key. You
should enter the account name or the key when the
device should communicate with other plaorms via
EHome protocol.
•
EHome key range: 8 to 32 characters.
7.4.5 Set Wiegand Parameters
You are able to set the Wiegand direcon (send/receive) and the
Wiegand mode (Wiegand 26/Wiegand 34).
Steps
1.
Move the cursor and select Comm. → Wiegand .
2.
Set the Wiegand parameters.
Direcon
Send
The device can connect to the access controller to upload
the card No. bia the Wiegand 26 or the Wiegand 34
mode.
Receive
The terminal can connect to the Wiegand card readers.
No need to
congure the Wiegand mode.
Mode
Wiegand 26 and Wiegand 34 can be selected. The default
Wiegand mode is Wiegand 34.
Note
If you change the external device, and aer you save the
device parameters, the device will reboot automacally.
7.4.6 Set RS-485 Parameters
The face recognion terminal can connect external secure door
control unit or card reader via the RS-485 terminal.
Steps
1.
Move the cursor and select Comm. → RS-485 on the Home
page to enter the RS-485 page.
Figure 7-4 Set RS-485 Parameters
2.
Select an peripheral type according to your actual needs.
3.
Press ESC and select Yes to save the
sengs.
7.5 Person Management
7.5.1 Add Person
You can add users by seng the ID No., the user name, and the
card No. You can also record the user ngerprint, set the
16