8.4 Function Specifications
153
8
Demand period
15 min., 30 min. and 1 hour
Real-time control
ON / OFF (both starting from zero seconds)
Settable start time
Year, month, day, hour and minute (24-hour system, valid for the
specified time)
Settable stop time
Year, month, day, hour and minute (24-hour system, valid for the
specified time)
Version information
Firmware version display
Display language
English, Chinese, Korean, Japanese
Beep sound
ON, OFF
Screen colors
COLOR1, COLOR2, COLOR3, COLOR4, MONO
LCD backlight
Always ON/Auto, OFF (1, 5, 15 and 30 min., and 1 hour)
LCD contrast
-30 to +0 to +20
Clock setting
Year, month, day, hour and minute (24-hour system)
System reset
System reset returns the instrument to factory default setting condi-
tion (time and display language are not reset)
Serial No. information
Serial No. information
Version information
Version information
Event settings
Manual events and Start and Stop events cannot be changed (always
on)
Basic setup
Basic Setup Contents
Setting Contents (factory defaults in bold)
Event ON/OFF and Setting Value
Voltage Swell OFF ON (100 to 150%)
Voltage Dip OFF ON (0 to 100%)
Interruption OFF ON (0 to 100%)
Inrush current OFF 0.0 A to 5.000 kA (set in 1 A steps)
Transient Overvoltage OFF ON
Timer OFF 1, 5, 15 and 30 min., 1, 2 and 12
hours, and 1 day
Setting Item Setting
Frequency AUTO
Nominal Line Voltage AUTO
Interval AUTO
Voltage Swell 110%
Voltage Dip 90%
Interruption 10%
Transient Overvoltage ON