138 / 183
Assembly and Commissioning Instructions Servo amplifier D1-N
•
Software controller enable. If “HW enable” and “enable”
are active, the motor is energised.
ATTENTION: When first energising after resetting the
drive amplifier, commutation is undertaken first.
•
Software controller enable is deactivated.
•
Sets the current position to 0.
•
Stops the current movement immediately. Motor remains
subject to control and can be moved further using another
motion command.
•
“Hardware enable” is active
•
“Software enable” is active
•
Motor is subject to control and is ready
•
Motor has commutated.
•
Motor is in motion (is 1 for as long as the nominal speed is
not 0)
•
Motor/axis is referenced to the reference point.
•
Motor is energised in stepper mode (not subject to con-
trol).
•
Defines the units in which all values are entered and dis-
played.
•
Traversing speed.
•
Acceleration
•
Delay
•
Delay for emergency stop
•
Defines the jerk limitation. 1 means maximum jerk. Higher
values result in a gentler start.
•
Amplification factor which impacts on the “settling time”
and position errors. Must be adapted depending on appli-
cation and load.
Note: The positions and spacing are entered in the unit selected under “Position
Units”.
•
Motor continually moves this way and that between posi-
tion P1 and position P2. Pause between the movements
can be defined under “Delay time”.
•
Motor moves away from current position by “Distance”.
•
The motor can be moved positively and negatively with the
two buttons. The motor moves for as long as the button is
pressed.
•
Starts homing