EasyManuals Logo

Honeywell MX7 Tecton User Manual

Honeywell MX7 Tecton
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
6 - 8
Auto Re-Launch
Default is Enabled.
When enabled for a specific application. automatically re-launches it (subject to the specified Auto Re-Launch
Delay in seconds) after it terminates. This option allows the Administrator to disable the re-launch operation.
AppLock cannot prevent all applications from closing. When an application that AppLock cannot prevent from clos-
ing terminates, perhaps because of an error condition, AppLock re-launches the application when this option is
enabled.
Note: If Allow close (page 6-8) is enabled and both Auto Re-launch and Manual (Launch) are disabled, the
application cannot be restarted for the end user or by the end user after the application terminates.
Retries
Default is 0 tries. Retries is the number of times AppLock will try to re-launch the application. The retry count
is reset after an application is successfully launched and controlled by AppLock. Valid values are between 0
(no tries) and 99 tries or -1 for infinite. Infinite tries ends when the application successfully launches.
Delay
Default is 0 seconds (no delay). Delay is the amount of time AppLock waits prior to re-launching an applica-
tion that has terminated. The delay is specified in seconds. Valid values are between 0 (no delay) and 99 sec-
onds.
AppLock must also be configured to automatically re-launch an application. To AppLock, application termina-
tion by the end user is indistinguishable from application termination for any other reason.
Manual (Launch)
Default is Disabled.
Enabling this option allows the end user to launch the specified application(s). Upon bootup completion an appli-
cation with Manual enabled is listed on the Switchpad accompanied by a checkmark that indicates the application
is currently active or available for Launching. When an application name is tapped by the end user, the application
is launched (if inactive) and brought to the foreground.
Applications set up with Manual (Launch) enabled may or may not be launched at bootup. This function is based
on the application’s Auto At Boot setting. The applications have been listed as approved applications for end user
manual launch using the Switchpad menu structure. The approved applications are listed on the Switchpad. A
checkmark indicates the applications active status.
When Manual (Launch) is disabled for an application, and Allow Close is enabled for the application, when the end
user closes the specific application it is no longer available (shown) on the Switchpad.
When Auto At Boot and Manual (Launch) are both disabled for a specific application, the application is 1) not
placed on the list of approved applications for end user manual launch and 2) never launched, and 3) not dis-
played on the Switchpad.
Allow close
Default is Disabled. When enabled, the associated application can be closed by the end user.
This option allows the administrator to configure applications that consume system resources to be terminated if
an error condition occurs or at the end user’s request. Error conditions may generate a topmost popup requiring
an end user response, memory resource issues requiring an end user response, etc. Also at the administrator’s
discretion, these types of applications can be started manually (see Manual [Launch]) by the end user.

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g

Related product manuals