232
Failure to apply a PoE profile to a PI
Symptom
PoE profile application for a PI failed.
Analysis
Possible reasons include:
• Some configurations in the PoE profile are already configured.
• Some configurations in the PoE profile do not meet the configuration requirements of the PI.
• Another PoE profile is already applied to the PI.
Solution
To resolve the problem:
• In the first case, remove the original configurations.
• In the second case, modify the configurations in the PoE profile.
• In the third case, remove the application of the undesired PoE profile from the PI.