2. Press the Unload Button once per second until either P or U appears in the SCD.
Function Code P or U will appear in the SCD to indicate the current setting for
Post Error Reporting. If you cycle past the desired code, press the Unload
Button once per second until the code reappears.
3. Exit Maintenance Mode if you do not want to change the current setting for
Post Error Reporting. For instructions, see “Exiting Maintenance Mode” on
page 72.
4. To disable Post Error Reporting, Press and hold the Unload Button for three
seconds while P appears in the SCD. The SCD changes to U after you release
the Unload Button.
5. Press the Unload Button once per second to select another Maintenance Mode
Function. To exit Maintenance Mode, refer to “Exiting Maintenance Mode” on
page 72.
Function Code U: Post Error Reporting Disabled
When Post Error Reporting is disabled, deferred-check conditions are not reported
to the host and temporary errors are not reported in the sense data. This is the
normal (default) setting for the drive. When the drive has Post Error Reporting
disabled, Function Code U will be displayed in Maintenance Mode. The drive will
default to Post Error Reporting disabled after a reboot or power off/on cycle.
1. Place the drive in Maintenance Mode. For instructions, see “Entering
Maintenance Mode” on page 72.
2. Press the Unload Button once per second until either P or U appears in the SCD.
Function Code P or U will appear in the SCD to indicate the current setting for
Post Error Reporting. If you cycle past the desired code, press the Unload
Button once per second until the code reappears.
3. Exit Maintenance Mode if you do not want to change the current setting for
Post Error Reporting. For instructions, see “Exiting Maintenance Mode” on
page 72.
4. To disable Post Error Reporting, Press and hold the Unload Button for three
seconds while P appears in the SCD. The SCD changes to U after you release
the Unload Button.
5. Press the Unload Button once per second to select another Maintenance Mode
Function. To exit Maintenance Mode, refer to “Exiting Maintenance Mode” on
page 72.
80 7226 Storage Device Enclosure Setup, Operator and Service Guide