For IBM Power Systems with IBM i (OS) Operating System
Verify that the host system software configured the 7226 installed devices
automatically by doing the following:
__ 1. Log into the IBM i (OS) Operating System level 6.1 or later.
__ 2. At the command line, type
wrkhdwrsc *stg
and then press Enter. The "Work with Storage Resources" screen displays.
__ 3. In the Type-Model column, find the adapter to which the Tape Drive has
just been attached.
__ 4. In the Opt column, type 9 next to the adapter, then press Enter. The Work
with Storage Controller Resources screen now displays the adapter on the
first row. The Tape Drive should be listed below. In the Type-Model column,
the Tape Drive displays as xxxx–001, where xxxx is the device type feature
code. In the Resource column, the Tape Drive displays as TAPxx, where xx
is a number that is assigned automatically by the host system. If the Tape
Drive displays below the adapter, then the host system software has
configured it automatically.
Note: If the 7226 Tape Drive Feature that you are configuring does not appear
below the adapter, check your installation procedure to ensure all settings
are correct and the cables are connected correctly and securely. Try the
procedure again. If the Tape Drive that you are configuring does not appear
below the adapter on your screen, contact your trained service personnel. Be
aware this may be a chargeable call.
__ 5. Press F12 until you return to the Main Menu.
__ 6. (Optional) To verify that the Tape Drive can process the tape correctly,
perform the following:
a. At the command line, type
vfytap
and then press Enter. The Verify Tape (VFYTAP) display appears.
b. In the Device field, type the name of the device (for example, TAP16 ),
then press Enter. The Tape Device Test Menu displays.
c. Select one of the following tests, then follow the instructions on each
screen:
v 1 Basic read/write test (takes approximately three minutes)
v 2 Read/write reliability test (takes approximately 30 minutes)
d. Follow the instructions on the screen to complete the test for the device.
If the tape verification test fails, check your installation procedure to ensure all
settings are correct and the cables are connected correctly and securely. If you are
still unable to verify that the Tape Drive can process the tape correctly, contact
your trained service personnel. Be aware that this may be a chargeable call.
This completes the installation for IBM Power Systems with IBM i Operating
System.