Using the Terminal Emulation MenusChapter 4
120 TE 2000
5250 Terminal Emulation Programmer’s Guide
Lengths Options
The Lengths Options menus determine the maximum and minimum
length for a specific bar code symbology. Setting the length of enabled bar
codes helps the terminal determine if a scanned bar code is valid and im-
proves response time. The length options must be set for each enabled bar
code. Enter this information in the order listed.
1 Key in the maximum length (0–99), then press [Enter]. For the 700 Se-
ries Computer, the CK30 Handheld Computer, or the CV60 Vehicle Mount
Computer, set this as high as you intend to set the minimum length.
2 Key in the minimum length (0–99), then press [Enter].
3 Fixed-length entries override the maximum and minimum length
entries (minimum and maximum are used for chosen codes). If fixed
lengths are not needed for the enabled bar code, enter zero (0).
Enter the f ixed length (0–99), then press [Enter].Uptofourprompts
to set another f ixed length will appear. Enter zero (0) for the unused
fixed lengths. Note that I 2 of 5 only supports fixed lengths 1 and 2. Entries
in 3 and 4 are ignored.
4 Enter the number of characters (0–15) to drop from the front (leading)
edge of the scanned bar code, then press [Enter].
5 Enter the number of ch aracters (0–15) to drop from the rear (trailing)
edge of the scanned bar code, then press [Enter].
700 Series, CK30, CK31, CV60 Exceptions
The following exceptions apply only to the 700 Series, C K30, CK 31, or
CV60 Terminals:
S Codabar, Str 2of5, Int 2of5, and CI 2of5 bar code symbologies set the
length, if fixed-length 1 is non-zero, to three fixed-length entries equal
to the first three fixed-lengths (f ourth fixed-length is ignored). Other-
wise, the length is set to greater than or equal to the minimum length.
S Code 39, Code 128, Code 93, and Plessey set the length to any length
greater than or equal to the minimum length.
S UPC/EAN and Code 11 lengths are not used ANY is allowed.
S Codabar options will not decode less than two data characters (four
characters including Start and Stop).
S CI 2of5 options override Str 2of5 options, if both CI 2of5 and Str 2of5
are selected.
S EAN Add-on settings override UPC add-on settings, if both UPC and
EAN options are selected.
S If “Sys 1 UPCE” or “Sys 0 UPCE” is selected, then both UPCE number
system 0 and 1 are enabled.
S Code 11 does not support “No check digits. Select either 1 check digit
(Chk Dig 1) or 2 check digits (Chk Dig 2) according to your bar codes.
If neither check digit option is selected, then 2 check digits will be used
as a default.