Extended Commands—Chapter 7
329TE 2000
5250 Terminal Emulation Programmer’s Guide
Example of Scan Bar Code Parameters
The following example and chart show data for Scan Bar Code parameters.
Note that “b”indicatesa1-bytespace.
b#S07F32012211120012080108080bbbbbbbb
Column 1 Column 23Column 11 Column 36
Column Character Description
1 b Th i s column typically contains a s pace.
2 # Extended command.
3 S Scan Bar Code Parameter c ommand
4 0 No Control Byte 1 options are re turned
5 7 [ENTER] key terminates all scans, 12-volt laser is enabled,
Mod 10 Check Digit
6 F Bar code t ype is returned and concatenated
7–8 32 Maximu m length is 32 characters
9–10 01 Minimum length i s 1 character
11 2 Decode UPC System 0
12 2 EAN is enabled
13 1 Encoded code 39 is enabled
14 1 Plessey is enabled
15 1 Mod 10 first digit is checked
16 2 ABC Codabar is enabled
17 0Code11isdisabled
18 0 Code 93 is disabled
19 1 Code 128 is enabled
20 2 Straight 2 of 5 is enabled
21–22 08 Straight 2 of 5 maximum length is 8
23–24 01 Straight 2 of 5 minimum length is 1
25–26 08 Straight 2 of 5 1st fixed length is 8
27–28 08 Straight 2 of 5 2nd fixed length is 8
29 0 Interleaved 2 of 5 is disabled
30–31 bb No change from current s e tting
32–33 bb No change from current s e tting
34–35 bb No change from current s e tting
36–37 bb No change from current s e tting