Extended CommandsChapter 7
311TE 2000
5250 Terminal Emulation Programmer’s Guide
Return Codes for Receive Only
Line 24, Column 1, is the r eturn status byte. The host application defines
the 1-byte return status field location. The following chart lists return sta-
tus codes.
Code Description Column
0 Good status, transaction complete. (None)
1 Not enoug h memory. Or, incorrect setting for speed, nu mber of data bi t s, or number of
stop bits.
4, 6, 7
2 No delimiter (#) on data stream. (None)
6 Improper retu rn field. (None)
7 Hexadecimal value is outside the rang e of 00–0F . 15–16, 19–20
8 Error in AID code. (None)
9 Incorrect se tting for maximum characters to re ceive. 13–14
A Incorrect se tting for delimiter character. 15–16
B Incorrect setting for number of delimiter characters. 17–18
D Incorrect setting for start characte r. 19–20
E Incorrect se tting for data parity. 5, 22
f/F* Timeout. (None)
o/O* Overrun of UART receive register. (None)
p/P* Data parity or framing error. (None)
R Syntax error from RD5500 Remote Display (not the expected ch aracter; no character error
was detected). (Applies only to the 17XX Terminal.)
(None)
* An uppercase letter indicates an error from the RS-232 device. A lowercase letter indicates an error from the
RD5500 Re mote Display (applies only to the 17XX T erminal).