System Messages and Parameter Errors
The terminal’s display r eserv es a line for status information. The statu s line
can display system (nonlocal) information such as a message waiting from
the host computer, help messages in response to the Help key, or the sys-
tem request state of the terminal. You can program the location of the sta-
tus line through the Start of Header order.
System codes can also appear on the status line. (On 17XX and 59XX Ter-
minals, the system codes do blink.) The par ameter errors displayed when
the stated condition occurs are listed on the next page. Unless otherwise
noted in the table, the terminal’s Reset key restores the status line and
returns to the keying mode in effect when the problem occurred.
Code Description
0005 Attempt to enter data when not in a field.
0006 A key other than a data key or [ENTER] was pressed in the system request
state.
0007 A mandatory entry field h as not had data put into it.
0008 The field is alpha only, and an i nvalid key w as pressed.
0009 The field is nume ric only, and an invalid key was pressed.
0010 The field is signed numeric, and an invalid key was pressed.
0011 Data cannot be entered into the last byte of a signed numeric field.
0012 No room in field for insert. The field is full or on the last byte.
0013 Cannot leave field while in insert mode.
0014 Fieldismandatoryfillandcannotbeexiteduntilfilled.
0015 MOD 10 or MOD 11 Check has failed on field.
0016 Field error: Cannot be use d in field that is not signed nu meric.
0017 Attempt to use [FIELD EXIT] key in unfilled, mandatory fill field.
0018 Only a nondata key can be u s ed to exit this field; for example, [FIELD EXIT].
0019 [DUP] key not allowed in this field.
0020 Cannot use AID-generating key to exit signed numeric or right-adjusted field.
Must use [FIELD EXIT].
0021 Cannot exit a mandatory enter field w ithout entering data.
0023 Invalid hex value entered.
0026 The [FIELD-] key was presse d, but the last character of the field was not 0-9.
0099 An invalid key was pressed before the terminal was in session. Only
[SYS REQ] is allowed.
C00 An invalid 5250 command was rec eived. This sequence of bytes is se nt to th e
host:0110030101.
PXX System code where “XX” is the parameter error .
When a 5250 command contains invalid parameters, system code “PXX”
appears on the bottom line of the display. (On 17XX and 59XX Termi-
nals,thesystemcodesdoblink.)The“XX”inthesystemcodeindicates
the type of parameter error.
The message sent to the host is: 01 10 05 01 XX, where “XX” is the same
parameter error that was put in the terminal’s display.