PLDC01938
REVISION 00
01/06/2011
TECHNICAL DEPT.
Stavale
- date 05/09/2011
101/195
46
As the actuator button Y1 (of the micro switch Y) is in the inactive position, thus normally closed (NC), there
must be continuity and there will be movement on the digital multimeter display.
47
By manually unscrewing the rod A1 completely, move the position of cam K until the actuator button Y1 of
the micro switch Y is pressed.
48
Check the grey and red wires B2, keeping the plug on the wire D1 connected to the terminal of the grey and
red wires B2, position 2 of the connector B, and the plug on the wire D2 on the terminal of the white wire B5,
position 5 of the connector B.
49
Connect the opposite ends of the wires D1 and D2 to the digital multimeter and check electrical continuity.
50
The micro switch Y is no longer in the NC inactive position, breaking electrical continuity. There must not
therefore be continuity and there should be no variations on the digital multimeter display.
51
Move the red wire D1 from position 2 to position 4 of the connector B and connect to the plug of the green
and pink wires B4.
PHOTO 217
OK
D1
D2
B2
B5
K
B
X
X1
2 5
PHOTO 218
NO
D1
D2
B2
B5
B
2 5
Y
K
Y1
PHOTO 219
OK
K
D1
D2
B
B4
B5
4 5
Y1
Y