127/195
17
Switch the machine off by turning the ignition key to position "0".
18
Connect the female “bridge” connector C to the male connector B in the main wiring.
19
Switch the machine on by turning the ignition key to position "1".
20
In this configuration, no detergent tank alarm should be displayed on the control panel board, otherwise
check:
20a
The float switch wiring, there must be continuity between the yellow wire (on the connector) and the
negative pole of the batteries and between the red wire (on the connector) and pin 3 of the connector CN5.
20b
Replace the control panel board with a new one.
It is very important to check correct operation and wiring of the float switch and
correct functioning of the messages on the control panel display. If for any reason
“no water” or “no detergent” were not displayed, the brushes would continue to
wash without detergent, risking ruining the brushes or surface being washed.
PHOTO 272