PLDC01938
REVISION 00
01/06/2011
TECHNICAL DEPT.
Stavale
- date 05/09/2011
75/195
B1.1 Checking the current draw of the suction motor
1
Make sure the batteries on the machine are charged (36 V ± 1 V).
2
Obtain a clamp meter able to read up to 200 A (amps), see photograph below.
3
Move the machine to the tank draining area and completely empty both tanks.
4
Move the machine onto a flat dry area of floor.
5
Make sure there is sufficient space around the machine to carry out the tests safely.
6
For convenience, enter the user programming board and disable “AutoPowerOFF”.
7
To change AutoPowerOFF to OFF, follow the instructions in the annexed USER PROGRAMMING sheet or
proceed as described below.
A Press the display button A for at least 10 seconds until the first selectable parameter, the language, is
displayed.
B Press the display button A again to scroll through the menu until you reach "Program 1 AutoPowerOFF ON".
See also the instructions in paragraph A1.1.
C Press the "+" and "-" buttons B to change the setting from "ON" to "OFF"
D Keep the display button A pressed for a few seconds to save the new settings.
8
Turn the ignition key C to position "0".
9
Apply the electrical bridge D to the "operator present" micro switch (under the seat).
C
PHOTO 165
D
PHOTO 163
B
PHOTO 164