EasyManua.ls Logo

JRC JMA-7710-6 - Magnetron Current, Running and Transmission Time

JRC JMA-7710-6
303 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 – 7
8.1
8.1.2.8 Magnetron Current, Running and Transmission Time
This test is used to check the magnetron current by displaying the magnetron current bar.
Procedures
Procedures
1. Follow procedures 1 to 2 in subsection 8.1.2.3.
The DIAGNOSTIC 1 menu appears.
The magnetron current bar, the totals of the running and transmission times are
displayed.
RANGE JMA-7725 JMA-7710
0.125 to 0.75nm 1 to 3 scales 1 to 2 scales
1.5nm 5 to 8 scales 3 to 5 scales
3nm 5 to 8 scales 3 to 5 scales
6 to 96 and 120 nm 5 to 8 scales 3 to 5 scales
Exit
Exit
2. Press the
SUB
MENU
key.
The running time indicates the time when the power has been turned on and the transmission time indicates
the total time when transmission has actually been conducted.
Diagnostic 1
1. SENSOR TEST
2. LINE TEST
3. ATA STATUS
4. ROM VERSION
5. ERROR LOGGING
MAG. I.
RUNNING TIME XXXX HR
TX TIME XXXX HR
DIAGNO
STIC 1
0. PREV

Table of Contents