3 – 13
3.2
3.2.9 Rejecting Radar Interference
If you'll watch the RADAR BEACON and the SART, set IR as follows.
IR OFF
Procedures
1. Press the
MAIN
MENU
key to open the MAIN MENU.
2. Press the
6
key to select "IR".
3. Press the
6
key to select "OFF", "IR1", "IR2" or "IR3" according to
the radar interference status.
"IR1", "IR2" or "IR3" then appears on the upper right of the screen to display the
interference rejection circuit operation. "IR3" is most effective for the radar interference.
4. Press the
ENT
key.
Exit
5. Press the
MAIN
MENU
key.
Main menu
1. RADAR/TRACK BRILL [DAY1]
2. RR/VRM/EBL BRILL [DAY1]
3. ATA BRILL [DAY1]
4. GRAPHIC DATA BRILL [DAY1]
5. PROCESS OFF PROC1 PROC2 PROC3
6. IR OFF
IR1 IR2 IR3
7. FLOATING EBL
OFF ON
8. VECTOR
TRUE RELATIVE
9. GRAPHIC DATA DISP OFF
3.2.10 Adjusting Control Panel Brilliance [PANEL]
Procedures
Brilliance increases in the four levels every time the
PANEL
key is pressed
and pressing it again returns the system to the original status.
Attention
MAIN MANU

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-7710-6 and is the answer not in the manual?

JRC JMA-7710-6 Specifications

General IconGeneral
BrandJRC
ModelJMA-7710-6
CategoryMarine Radar
LanguageEnglish

Related product manuals