8 – 45
8.5
8.5.6.2   Partial Master Reset
This function is used to set the same settings as on shipment.  Since the contents set by the user are cleared,
only our service personnel is allowed to use this function.
Procedures
1. Follow procedures 1 to 3 in subsection 8.5.6.1 to open the MAINTENANCE
MENU.
2. Press the 
4
 key to select "PARTIAL MASTER RESET".
3. Press the 
4
 key to set the system in the partial master reset standby
mode.
4. Press the 
ENT
 key to reset or the 
CLR
 key not to reset according to
the direction on the screen.
After resetting, the screen which appears after turning the power on is displayed.
Exit
5. Press the 
SUB
MENU
 key.
8.5.6.3   Total Master Reset
This function is used by our service personnel after the software is written.  Users are requested never
to use this function.
8.5.6.4   Internal Setting to Card 2
This function is used to write the contents internally set into card 2.  Use this function after inserting a
memory card for writing to the lower side of the card slot.
Procedures
1. Follow procedures 1 to 3 in subsection 8.5.6.1 to open the MAINTENANCE
MENU.
2. Press the 
6
 key to select "INTERNAL SETTING to CARD 2".
3. Press the 
6
 key to set the system in the standby mode.
4. Press the 
ENT
 key to write or the 
CLR
 key not to write according to
the direction on the screen.
After writing, a message informing the completion of writing appears.
Exit
5. Press the 
SUB
MENU
 key.