7-3
9. After power-on operation, perform the operation in according to the
section in “7.1.7 Setting of True Bearing Value”, and then make sure of
the radar video and the operation with the true bearing value.
10. If the true bearing value of the radar equipment is reversed, change the
setting of the switch S1-4.
Table 7-1 Gyro and Log Select Switches (S1 DIP Switch)
S1 SETTING TABLE
1 2 3 4 5 6 7 8
STEP ON
SYNC OFF
360X OFF OFF
180X ON OFF
90X OFF ON
36X ON ON
NOR OFF
GYRO SIG
DIRECTION
REV ON
PULSE OFF
TYPE
SYNC ON
Don’t care OFF
800P/360X
OFF OFF
400P/180X
ON OFF
200P/90X
OFF ON
LOG SIG
PULSE
NM
100P/30X
ON ON
Table 7-2 Gyro and Log Select Switches (S2 DIP Switch)
S2 SETTING TABLE
S2 1 2 3 4 5 6 7 8
ON
LOG ALARM
OFF
ON GYRO
SIMULATOR
OFF
ON
LOG SIMULATOR
OFF
N.C.
Don't care any
5s ON GYRO ALARM
TIME
0.5s OFF
NMEA(HDT/THS) ON HEADING SENSOR
SOURCE
GYRO SIGNAL OFF
4800 OFF OFF
9600 ON OFF
19200 OFF ON
OTHER SETTING
NMEA BAUDRATE
SETTING
38400 ON ON