Service and maintenance
Chapter 6 - page 6
M-HE.002.1003
Replace the damaged tubes as follows:
Disengage the hose clamps.
For easy disassembly you should cut the tube lengthways
near the hose column before removing it.
Align the hose clamps to the tube and slide the tube onto
the hose column without torsion.
Lift the teat cup by the inside of the teat cup head and
check if the position of the cup is fairly straight. Place the
teat cup tubes for the rear teats against one another as
much as possible, pointing away from the robot arm. Place
the teat cup tubes for the front teats against the robot arm
as much as possible. This creates a large amount of space
for the cows legs. If these requirements are not met, correct
the situation by turning the milk tubes near the teat cups
and slightly varying the length.
Ensure that the tubes remain free of torsion. Fit the hose
clamps in such a way that they can not disturb the dip spray
pattern or obstruct movement in any other way.
Tighten the hose clamps without turning the tubes.
Cleaning agents (detergents):
Check the acid stock within the container located below the
red coloured sticker (and hose) with Astri
®
-cid on it
(figure 6.9). The container is placed at the rear LH side of
the box. Replace the container by a full one if the level is
too low. Also check if the suction pipe is still positioned
sufficiently into the liquid to ensure proper sucking action.
For more information regarding capacities refer to
section 6.1.1 ’Fluids and lubricants’.
Check the alkaline stock within the container below the
blue coloured sticker (and hose) with Astri
®
-lin on it. The
container is placed at the front LH side. Replace the
container by a full one if the level is too low. Also check if
the suction pipe is still positioned sufficiently into the liquid
to ensure proper sucking action.
Check the LELYWASH
®
/brush cleaning agent stock within the container below the green coloured sticker
(and hose) with Astri
®
-L on it. The container is placed at the front LH side of the box. Replace the container
by a full one if the level is too low. Also check if the suction pipe is still positioned sufficiently into the liquid to
ensure proper sucking action.
Figure 6.8 Milk and pulsation tubes
Figure 6.9 Cleaning agent reservoir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LELY ASTRONAUT and is the answer not in the manual?

LELY ASTRONAUT Specifications

General IconGeneral
TypeAutomatic Milking System
ManufacturerLely
ModelAstronaut
Milk Yield RecordingYes
Cleaning SystemAutomatic
Energy ConsumptionVaries depending on model and usage
WeightVaries depending on model
DimensionsVaries depending on model
SoftwareLELY T4C
User InterfaceTouchscreen
ConnectivityEthernet
Milking Capacity60-70 cows

Related product manuals