Figure 358. Cable routing for six SAS/SATA drives and two AnyBay drives and two NVMe front drive bays with a 16i CFF
HBA/RAID adapter (Gen 3 or Gen 4)
Table 165. Mapping between one front SAS/SATA backplane and a CFF RAID adapter
Backplane/adapter
From To
Front BP (SAS)
1 SAS 0–3 1 C0
2 SAS 4–7 2 C1
CFF RAID adapter
3 MB input
3 PCIe 3
Front BP (power)
4 Power and sideband
4 Power port for front BP
Front BP (NVMe)
5 NVMe 6–7
5 PCIe 2
6 NVMe 8–9
6 PCIe 1
10 x 2.5'' AnyBay (Gen 5)
See this section to understand the cable routing of 10 front AnyBay drives with 10 x 2.5'' backplane (Gen 5)
installed.
To connect cables for a 7mm drive backplane, refer to
“7mm drive backplane” on page 270.
To connect cables for M.2 drives, refer to
“M.2 drive backplane” on page 267.
To connect cables for rear NVMe drives, refer to
“Rear NVMe backplane cable routing with 10 x 2.5'' AnyBay
backplane (Gen 5) installed” on page 273.
Chapter 6. Internal cable routing 423