Network
Network
• OCP module
Notes:
• The server features three OCP slots: OCP 1 and OCP 2 are located on the rear side, and OCP 3 is positioned at the
front when the customer configures the front adapter assembly.
• OCP module 1 and front OCP module 3 are alternatives. When front OCP module 3 is configured, OCP module 1
will be disabled.
• OCP module 1 and front OCP module 3 take priority over OCP module 2.
RAID support
RAID support
Onboard NVMe ports with software RAID support (Intel VROC NVMe RAID) and JBOD
• Intel
®
VROC standard: requires an activation key and supports RAID levels 0, 1, and 10
• Intel
®
VROC Premium: requires an activation key and supports RAID levels 0, 1, 5, and 10
• Intel
®
VROC Boot: requires an activation key and supports RAID level 1 only
System fan-pack
System fan
• Supported fan-pack types:
– Standard fan-pack 4056 (28000 RPM, single rotor)
– Performance fan-pack 4056 (28000 RPM, dual rotors)
• Fan redundancy: N+1 redundancy, one redundant fan rotor
– One processor: three hot-swap dual-rotor system fan-packs (one redundant fan rotor)
– Two processors: four hot-swap dual-rotor system fan-packs (one redundant fan rotor)
Notes:
• The redundant cooling by the fans in the server enables continued operation if one rotor fails.
• When the system is powered off but still plugged in to AC power, and XCC has detected that OCP modules are
installed, fan-pack 2 and 3 may continue to spin at a much lower speed. This is the system design to provide proper
cooling.
6 ThinkSystem SR630 V4 User Guide