Rack rear
Figure 86. Securing the server to the rear of the rack
After you finish
1. Reconnect the power cords and any cables that you removed.
2. Power on the server and any peripheral devices. See
“Power on the server” on page 74.
3. Update the server configuration. See
“Complete the parts replacement” on page 288.
Air baffle replacement
Follow instructions in this section to remove and install the air baffle.
Note: Air baffles are unavailable when the performance heat sink, Processor Neptune
TM
Air Module (NeptAir)
or Processor Neptune
TM
Core Module (NeptCore) is installed.
•
“Remove the air baffle” on page 97
• “Install the air baffle” on page 99
Remove the air baffle
Follow instructions in this section to remove the air baffle.
About this task
Depending on the model, your server might not have an air baffle installed. The air baffle you want to remove
might be different from following illustrations, but the removal method is the same.
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
Chapter 5. Hardware replacement procedures 97