<asset_tag>
The server asset tag number.
Type aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is
the asset tag number.
[access_method]
The access method that you select to access the target server.
Online KCS (unauthenticated and user restricted):
You can directly delete [access_method] from the command.
Online authenticated LAN:
In this case, specify below LAN account information at the end of the OneCLI
command:
--bmc-username <user_id> --bmc-password <password>
Remote WAN/LAN:
In this case, specify below XCC account information and IP address at the end of the
OneCLI command:
--bmc <bmc_user_id>:<bmc_password>@<bmc_external_IP>
Notes:
<bmc_user_id>
The BMC account name (1 of 12 accounts). The default value is USERID.
<bmc_password>
The BMC account password (1 of 12 accounts).
System fan-pack replacement
Use this information to remove and install a system fan-pack.
“Remove a system fan-pack” on page 279
“Install a system fan-pack” on page 281
Remove a system fan-pack
Use this information to remove a system fan-pack. You can remove a hot-swap fan without powering off the
server, which helps you avoid significant interruption to the operation of the system.
About this task
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
Chapter 5. Hardware replacement procedures 279

Table of Contents