Figure 250. Installing M.2 drive assembly
a.
Ensure that the drive tray handle is in the open position. Slide the drive into the drive bay
until it snaps into position.
b.
Close the drive tray handle to lock the drive in place.
After you finish
1. Complete the parts replacement. See
“Complete the parts replacement” on page 288.
2. Use the Lenovo XClarity Provisioning Manager to configure the RAID. For more information, see:
https://pubs.lenovo.com/lxpm-overview/.
Remove the rear M.2 backplane
Follow the instructions in this section to remove the rear M.2 backplane.
About this task
Attention:
Read
“Installation Guidelines” on page 57 and “Safety inspection checklist” on page 58 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 75.
Keep static-sensitive parts in their static-protective packages until installation to prevent exposure to
static electricity. Handle the parts with an electrostatic-discharge wrist strap or other grounding systems.
Place the parts on a static-protective surface.
Procedure
Step 1. Remove the top cover. See
“Remove the top cover” on page 282.
Step 2. Remove the rear M.2 cage, see
“Remove the rear M.2 cage” on page 247.
Step 3. Remove all rear M.2 adapter and drive assemblies, see
“Remove rear hot-swap M.2 interposer and
drive assembly” on page 243
.
Step 4. Disconnect all the cables connected to the M.2 backplane and record them.
Step 5. Remove the rear M.2 backplane.
Chapter 5. Hardware replacement procedures 245