• Read “Installation Guidelines” on page 57 and “Safety inspection checklist” on page 58 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 75.
• Keep static-sensitive parts in their static-protective packages until installation to prevent exposure to
static electricity. Handle the parts with an electrostatic-discharge wrist strap or other grounding systems.
Place the parts on a static-protective surface.
CAUTION:
When removing a new NeptCore module from the shipping box, lift out the cold plate assembly with
the shipping tray attached to prevent thermal grease on the cold plate assembly from damage.
Prepare the following screwdrivers to ensure you can install and remove the corresponding screws properly.
Torque screwdriver type list Screw Type
Torx T30 head screwdriver Torx T30 screw
Procedure
Step 1. Prepare your server.
a. Install the hose holder to the chassis.
Figure 157. Installing the hose holder
1. Loosen the screw on the system I/O board and processor board.
2.
Align the screw holes on the hose holder to the system I/O board and processor board.
And align the guiding pin of the holder to the rear wall.
3.
Tighten the screw to secure the holder to the system I/O board and processor board.
b. Open the hose holder cover.
162
ThinkSystem SR630 V4 User Guide