EasyManua.ls Logo

Lenovo ThinkSystem SR630 V4 - Power-Supply-Unit Leds

Lenovo ThinkSystem SR630 V4
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 FPGA heartbeat LED (green)
Description
The FPGA heartbeat LED helps you identify the FPGA status.
Blinking (about one flash per second): FPGA is working normally.
On or off: FPGA is not working.
Action
If FPGA heartbeat LED is always off or always on, do the following:
1. Replace the processor board.
2. If the problem remains, contact Lenovo Support.
4 DIMM error LEDs (amber)
Description When a memory module error LED is lit, it indicates that the corresponding memory module has
failed.
Action For more information, see
“Memory problems” on page 321.
Power-supply-unit LEDs
This topic provides information about various power supply unit LED status and corresponding action
suggestions.
The following minimal configuration is required for the server to start:
One processor in processor socket 1
One memory module in slot 7
One power supply unit
One HDD/SSD drive, one M.2 drive (if OS is needed for debugging)
Three system fan-packs
The following table describes the problems that are indicated by various combinations of the power-supply
unit LEDs and the power-on LED and suggested actions to correct the detected problems.
Figure 329. LEDs on a CRPS Premium power supply unit
Chapter 7. Problem determination 309