Loading...
2. You can mix drives of different types and different capacities in one system, but not in one RAID array.
And when you deploy a drive mix, install drives of lower capacity first.
3. Install NVMe drives in a descending bay sequence order, 9 8 7...
Thermal rules
This topic provides thermal rules for the server.
“Server models with front drive bays only” on page 71
“Server models with front and rear drive bays” on page 72
“Server models with NeptAir module” on page 72
“Server models with NeptCore module” on page 73
Server models with front drive bays only
This section provides thermal information for server models with front drive bays only.
Configuration
Backplane-less configuration
4 x 2.5'' NVMe
4 x 2.5'' NVMe with two low-profile PCIe adapters
Max. Ambient
Temp. (at sea level)
35°C 30°C
CPU TDP (watts)
185 ≤ TDP ≤ 205 205 < TDP ≤ 250 250 < TDP ≤ 300 300 < TDP ≤ 350
Heat sink
Standard Performance Performance Performance
Air baffle
x x x
Fan type
Standard Performance Performance Performance
DIMM capacity
≤ 64 GB 64 GB 64 GB ≤ 64 GB
Max. DIMM Qty.
32 32 32 32
Configuration
8 x 2.5'' NVMe
10 x 2.5'' NVMe
Max. Ambient
Temp. (at sea level)
35°C 30°C
CPU TDP (watts) 185 ≤ TDP 205 205 < TDP 250 250 < TDP ≤ 300 300 < TDP 350
Heat sink
Standard Performance Performance Performance
Air baffle
x x x
DIMM capacity
64 GB 64 GB ≤ 64 GB ≤ 64 GB
Fan type Performance Performance Performance Performance
Max. DIMM Qty.
32 32 32 32
Notes:
Chapter 5. Hardware replacement procedures 71