8400 StateLine C | Reference manual
Basic drive functions (MCK)
Holding brake control
376 L Firmware 11.00 - DMS 8.0 EN - 10/2011
[8-11] Close holding brake in automatic mode with actual value monitoring time (C02593/1 >0s)
Feedforward control
n C02581/1
: Switching threshold
o C02581/2
: Hysteresis for release
p C02581/3
: Hysteresis for application
q C02593/2
: Application delay
r C02593/1
: Actual value monitoring time
s C02589/1
: Application time

bMBrakeReleaseOut
0
0
bMBrakeReleased
CINH
t
t
t
t
nSpeedSetValue_a_

0
nMotorSpeedAct_a
nSpeedSetValue_a
