3 Configuring the I/O system in the »Engineer«
3.2 Mapping the real station layout in the »Engineer«
37
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10. Click the Start search button to start the search for connected devices.
The dialog box entitled Search for online devices is displayed with status messages
regarding the search.
•The Start-up wizard automatically establishes an online connection via the selected
interface in order to enable the read-out of data from the connected devices.
11. After the search has been completed, click the Close button to close the Search for online
devices dialog box.
12. In the Identified devices list field, select the devices that are to be included in the new
project to be created.
13. Click the Complete button.
The project is created with the selected settings. Below the project, all devices selected
before are listed in a flat structure.
Now there already exists an online connection to the selected devices as you can see
from the yellow highlighted device icon in the Project view.
Stop!
If you change parameters in the »Engineer« while the controller is connected online, the
changes will be directly accepted by the controller!