EasyManua.ls Logo

Lenze I/O system 1000 - Digital-I;O EPM-S207, EPM-S310 - time stamp function (example)

Lenze I/O system 1000
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17 20
2 Product description
2.4 Digital-I/O EPM-S207, EPM-S310 – time stamp function (example)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.4 Digital-I/O EPM-S207, EPM-S310 – time stamp function (example)
The example shows in which order the time stamp entries are stored and processed.
Here, a module is projected that assigns 20 bytes for five time stamp entries in the output area.
At the given times of the ticker, the outputs should have the following states:
The values of the table result in the following time diagram:
[2-1] Time diagram: Example time stamp function
Note!
The time stamp modules EPM-S207 and EPM-S310 can only be operated on front
modules with an integrated μs ticker.
Consecutive
number (RN)
Ticker value
in μs
Status DO 0
(Bit 7)
Status DO 1
(Bit 6)
Enable DO 0
(Bit 5)
Enable DO 1
(Bit 4)
0x01 6000 0 0 1 1
0x02 12506 1 0 1 1
0x03 34518 1 1 1 1
0x04 49526 0 0 1 1
0x05 54529 0 1 1 1
0x06 3500 1 1 1 1
0x07 12443 1 0 1 1
0x08 20185 0 0 1 1
0x09 30140 1 0 1 1
0x0A 37330 0 0 1 1
0x0B 40000 0 0 0 0

Table of Contents