4 Configuring the I/O system in the »PLC Designer«
4.3 Mapping the real station structure in the »PLC Designer«
59
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3.4 Configuring I/O modules on the CANopen bus coupler module
The following step-by-step instructions describe the manual mapping of the available station
layout in the device view of the »PLC Designer«.
Tip!
When an online connection has been established to the Lenze Controller, you can also start
an automatic search for available devices via fieldbus scan by executing the Start Search
command in the context menu of the CANopen Manager after adding the CANopen
Manager (step 6).
How to map the station layout of the »PLC Designer«:
Adding the CANbus
1. Go to the context menu of the Controller and execute the Add device... command:
2. Select the "CANbus" device in the Add Device dialog box:
3. Click Add Device to add the selected device to the Controller.
•The Add Device dialog box remains open.
Note!
The configuration of a Lenze Controller in a CANopen network must be created in the
»PLC Designer«, because the complete configuration is written to the connected slaves
when the Controller is started. This process overwrites the previous slave settings.