4 Configuring the I/O system in the »PLC Designer«
4.3 Mapping the real station structure in the »PLC Designer«
67
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3.4.3 Example: Commissioning of a counter (EPM-S601)
How to commission a counter using the example of an EPM-S601:
1. Create a new »PLC Designer« project.
For the general procedure, see the chapter "Create a new project in the »PLC Designer«
".
Defining the update and connection of gateway/control
2. Double-click the Lenze Controller in the Device view in order to open its settings and
properties in the Editor view.
3. Tick the following on the PLC settings tab:
4. Add the matching gateway on the Communication settings tab.
• Either via double-click or Add gateway... button