EasyManua.ls Logo

Lenze I/O system 1000 - Parameterising the Encoder Evaluation; Ssi - Epm-S604

Lenze I/O system 1000
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 PROFINET communication
9.9 Parameterising the encoder evaluation
539
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.9 Parameterising the encoder evaluation
9.9.1 SSI - EPM-S604
By integration of the GSE file VI010C19.gse you can specify all counter parameters via a hardware
configuration.
The following functions can be parameterised:
Read data: 6 bytes
Encoder value: current encoder value
Ticker value: After mains connection, a timer (s ticker) is started which restarts at 0 after 65535 s.
With every change of the encoder value, the time value of the timer is stored as 16-bit-s value
together with the count value in the input area.
Functions Description
SSI encoder parameters According to encoder data sheet
Operating mode Master mode or monitoring operation
Alarm response With definition of the comparison and limit values
Input area
Addr. Access Assignment
+0 Double word Encoder value
+4 Word Ticker value