4 Configuring the I/O system in the »PLC Designer«
4.3 Mapping the real station structure in the »PLC Designer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Adding I/O compound modules to the EtherCAT bus coupler module
7. Select the "EPM_S130" device in the device view:
8. Select the physically first I/O compound module in the Add Device dialog box and add it to
the device view by clicking the Add device button.
9. Proceed as described before to add all other available I/O compound modules of the Device
view.
• Sample representation:
10. Click the Close button to close the Add Device dialog box again.
Tip!
• If configured correctly and after "going online" and starting the PLC, all modules in the
device view are marked with the symbol.
• In the event of an error, i.e. if the configuration deviates from the physical arrangement,
the modules are marked with the symbol.